Call(WhatsApp Us)
+8615360806100Email Us
cherry@laeyo.comSee the factory by live video walkthrough
Book an on-site factory visit in GuangzhouMoving a conditioner to a new factory is rarely an ingredient-list problem. It is a measurement and process problem. Two sites can run the same formula and produce products that feel different in the…
Moving a conditioner to a new factory is rarely an ingredient-list problem. It is a measurement and process problem. Two sites can run the same formula and produce products that feel different in the shower — one slippery and easy to detangle, the other waxy, grippy, or heavy — because the conditioning effect is created by a structure (the lamellar gel network formed by fatty alcohols and cationic surfactants), not by a single ingredient on the INCI list. If you are transferring a Repair Conditioner, Repair Mask, or Leave-in where the consumer-visible promise is “easier combing” or “less breakage”, you need to compare performance with the same protocol, the same reference sample, and the same proxy metrics. This guide gives you the requests, the acceptance criteria, the timeline, and the failure modes to manage that comparison as a procurement project rather than a sample swap.
Informational only, not legal advice.
The fastest safe path is only available when the formula and raw-material grades stay identical. Everything that touches the gel network — cooling rate, shear, cationic grade, fatty alcohol ratio — must still be verified.
| Phase | Duration (fast / standard) | Buyer action | Manufacturer action | Evidence output |
|---|---|---|---|---|
| 1. Benchmark and reference lock | Week 1–2 / Week 1–3 | Ship a retained reference sample of the incumbent product; approve one protocol and the equivalence margin | Accept the protocol; assign one lab; confirm test methods | Signed protocol with test methods, tress lot requirements, n per cell, environmental conditions |
| 2. Material equivalence | Week 1–3 / Week 2–5 | Approve or reject each proposed raw-material substitution in writing | Submit material equivalence dossier with grade, activity, supplier and function | Raw-material comparison table with COA references and technical justification |
| 3. Pilot batches and proxy metrics | Week 3–6 (2 batches) / Week 4–8 (3 batches) | Review data batch by batch; do not release artwork yet | Run pilot batches; test pH, viscosity, solids, appearance; retain samples | Batch records plus proxy data table showing all batches inside spec |
| 4. Instrumental and panel comparison | Week 5–9 / Week 6–12 | Accept or reject equivalence; request a second panel if results are borderline | Run combing and breakage studies against the reference; recruit panel if needed | Study report with raw data, statistics and a supported / conditionally supported / not supported conclusion |
| 5. Packaging compatibility and stability | Week 4–12 (parallel) / Week 6–16 | Lock pack format and closure early; approve the compatibility protocol | Fill at line speed; run 40°C upright and inverted at 4 and 8 weeks plus drop test; start accelerated stability | Compatibility report, filled-pack stability data, pump or valve dose and force data |
| 6. Label and claims review | Week 6–10 / Week 8–12 | Freeze copy; sign off claims matrix and INCI | Reconcile artwork against formula version; confirm market-specific wording | Signed artwork proof with INCI reconciliation record |
| 7. First commercial batch and document handoff | Week 10–14 / Week 14–20 | Hold release until the document index is complete | Produce batch one; issue COA, SDS, stability summary, retention samples | Complete document index traceable to batch number and formula version |
Symptom: consumer panel describes the new batch as heavier and less slippery than the old one, although pH and viscosity are in spec.
Root cause: the lamellar gel network formed by fatty alcohols and cationic surfactant differs because the cooling rate, homogenisation time, or fatty alcohol ratio changed between tanks.
Prevention: freeze cooling rate, shear and addition temperatures in the master batch record, and add yield stress or a spreadability check alongside viscosity.
What to request from factory (Evidence): batch record with a cooling curve and shear parameters, viscosity at 24 hours and 7 days, yield stress data, and a blinded panel comparison against the reference sample.
Symptom: batch 1 at 12,000 cP, batch 3 at 8,500 cP; product thins after 8 weeks at 40°C.
Root cause: different cationic grade or activity level (for example a 25% versus 50% behentrimonium grade), inconsistent raw-material supplier, or pH drift affecting the gel network.
Prevention: specify grade and activity level in the raw-material spec, and measure viscosity at a fixed time after fill with spindle, speed and temperature defined.
What to request from factory (Evidence): three-batch viscosity data table, raw-material COAs with activity level, and accelerated stability viscosity trend.
Symptom: the new site reports “no significant difference” but the numbers cannot be set against your previous study.
Root cause: different tress lots, different washing cycles, different laboratory, or different humidity and temperature between the two studies.
Prevention: one protocol, one lab, and the reference sample included as a cell in every study.
What to request from factory (Evidence): protocol ID, tress lot ID, cycle count, environmental conditions, raw data, and statistical analysis.
Symptom: pump or flip-top dispenses in uneven surges or fails to prime; label edges lift after two weeks; leakage at the cap after 40°C storage.
Root cause: viscosity and shear-thinning behaviour of the new batch do not match the pump’s dose curve; adhesive and liner are incompatible with the fragrance system or with a PCR substrate’s surface energy.
Prevention: fill at production line speed, test actuation force and dose with the final viscosity, and run 40°C upright and inverted storage plus drop test before artwork is printed.
What to request from factory (Evidence): compatibility report, pump dose and force curve at the specified viscosity, label adhesion results, and photographs of filled packs after storage.
Symptom: COA, SDS or stability report missing at launch, or the stability report references a different formula version than the batch produced.
Root cause: no document version control tied to formula version, and no defined handoff owner.
Prevention: a signed document index with version numbers, issued before commercial release, cross-checked against the batch number.
What to request from factory (Evidence): document index listing COA, SDS, stability, micro, PET, compatibility report and claims matrix, each with version and date.
Symptom: allergen list on pack does not match the fragrance actually used, or complaints of scalp discomfort appear after launch.
Root cause: supplier substitution made under purchasing authority without change control, so exposure and tolerance were never re-assessed.
Prevention: contractual notification before any fragrance or preservative change, with mandatory safety file update and tolerance re-test assessment.
What to request from factory (Evidence): IFRA certificate, allergen declaration, safety assessment update memo, and documented tolerance re-test decision.
Symptom: marketplace listing rejected, or regulatory challenge over repair, growth or treatment language.
Root cause: product name and copy imply a mechanism beyond the tested benefit, pushing a cosmetic claim toward a drug boundary.
Prevention: run every claim and the product name through a claims matrix before artwork; keep wording anchored to tested combability and breakage outcomes.
What to request from factory (Evidence): claims matrix with evidence IDs, status flags per market, and regulatory sign-off on the final wording.
Symptom: preservative efficacy test fails, or micro counts approach the limit in the first commercial batches.
Root cause: water quality, hold times, tank sanitation or bulk storage temperature differ at the new site, while the preservative system was validated against the old process.
Prevention: re-run preservative efficacy and micro testing on product from the new site, and define maximum bulk hold time.
What to request from factory (Evidence): PET report with method and acceptance criteria, micro results against destination market limits, water quality records, and bulk hold time specification.
Subject: Conditioning performance transfer pack — [Brand] x [Factory] Share the master formula and process instructions, including heating and cooling rates and mix speeds, for the current and proposed sites. Confirm whether this is same-formula and same-raw-material, or a re-development. Provide specifications, suppliers and grades for the cationic surfactant, fatty alcohols, conditioning polymer, silicones and fragrance. State the activity level of each cationic raw material and confirm the new site can source the same grade. Attach three consecutive pilot batch records with in-process and release data. Provide pH, viscosity (spindle, speed, temperature, time after fill) and solids for each pilot batch. Run instrumental wet and dry combing against our retained reference sample in one laboratory. Include tress lot ID, number of tresses per cell, humidity, temperature, wash cycles and statistical analysis. Test combing breakage if the claim "helps reduce breakage" will be used. Provide the stability protocol, accelerated conditions, timepoints, real-time plan and retention sample policy. Provide the preservative efficacy method and micro acceptance criteria for the destination market. Fill production packs at line speed with the target fill weight. Run compatibility at 40°C upright and inverted for 4 and 8 weeks, plus a drop test. Confirm pump or valve dose and actuation force with the final viscosity. Attach the fragrance IFRA certificate, allergen declaration and plastic interaction notes. Provide label artwork proof against the final formula version and INCI list. Confirm COA, SDS and stability report all reference the same formula version. Provide the claims matrix with an evidence ID for every on-pack and e-commerce claim. Flag any claim implying hair growth, hair-loss prevention or scalp treatment before artwork is finalised. Provide the GMP certificate and latest audit report with open findings status. Confirm change control notification timelines in writing. State the document handoff date for the first commercial batch.
| Lever / Decision | Primary impact | What to do (specific) | Do NOT cut (red line) | Evidence needed (request) | Expected timeline effect |
|---|---|---|---|---|---|
| Benchmark protocol | Makes old and new data comparable | Fix one lab, one protocol, one equivalence margin before any sample is made | A defined statistical acceptance margin and n ≥ 10 tresses per cell | Signed protocol with methods and acceptance criteria | Adds 1–2 weeks up front, avoids 4–6 weeks of rework |
| Reference sample | Anchors the comparison | Ship retained incumbent product and include it as a cell in every study | Reference tested in the same run, same tress lot | Retention sample records with batch and age | Prevents a full study repeat |
| Gel-network process parameters | Controls feel, viscosity and stability | Record cooling rate, shear and addition temperatures as numbers with tolerances | Numeric cooling rate and mix speed in the batch record | Batch record with cooling curve and in-process checks | Adds 1 week, prevents batch-to-batch drift |
| Cationic and polymer grade equivalence | Prevents silent performance loss | Approve each substitution in writing by grade, activity level and function | Supplier COA with activity level for every cationic raw material | Material equivalence dossier | Adds 2–3 weeks if substitutes are proposed |
| Instrumental combing study | Substantiates combability and breakage claims | Run wet and dry combing plus breakage against the reference, single lab | Blinded, randomised design with raw-data summary | Study report with statistics and claim conclusion | 4–6 weeks; runs in parallel with stability |
| Panel or HUT design | Supports any percentage claim | Define exact question wording, population and timepoint before recruitment | Disclosed N and exact questionnaire text | HUT report with comparator and formula version | 4–8 weeks; only needed for AMBER claims |
| Proxy release specifications | Keeps future batches consistent | Set numeric ranges for pH, viscosity, solids and odour with method references | Viscosity method defined by spindle, speed, temperature and timing | Release specification and three-batch data set | No delay if agreed at pilot stage |
| Packaging compatibility | Prevents leaks and dispensing complaints | Fill at line speed and test dose, actuation force, 40°C inverted storage and drop | 8-week real-time or 40°C compatibility data before print | Compatibility report with pump curve and adhesion results | 8–12 weeks; start early, run in parallel |
| Document and claims handoff | Enables launch and audit readiness | Issue a version-controlled document index tied to batch and formula version | All regulatory documents referencing one formula version | Document index, claims matrix, COA, SDS, stability, micro, PET | 1–2 weeks; blocks release if missing |
Only if it was generated against your retained reference sample under the agreed protocol. A standalone report showing the new product performs well tells you nothing about equivalence to the product your customers already know.
It depends on claim level. Cosmetic-level wording such as conditions hair or easier combing usually needs finished-product evidence plus market review. Any number, duration, percentage or “clinically tested” style claim requires the study to be re-run on the new site’s material under stated conditions.
Three consecutive batches is the standard for demonstrating process control. Two can be acceptable on a same-formula transfer only when both are inside proxy spec and at least one is compared instrumentally to the reference.
Then it is a reformulation, not a transfer. Require a material equivalence dossier, re-benchmark against the reference, and re-check any claim that depends on the changed material. Do not accept “same INCI, different supplier” as automatically equivalent.
Roughly 10–14 weeks on the fastest safe path with an unchanged formula, and 14–20 weeks on the standard path once stability, compatibility and any consumer study are included. Packaging lead time is usually the constraint, not the laboratory.
If you are comparing conditioning performance across sites, start by sending your reference sample, target markets, claim list and current specification to the factory — that single package removes most of the back-and-forth. Request a Quote and include: target market(s), SKU count and formats (conditioner, mask, leave-in), brand positioning, packaging direction, and your target launch date. Quotes move faster when the claim level and the destination market are stated up front.